BLUGUARD SmartBus P900-V16N Instrukcja Użytkownika Strona 18

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 31
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 17
version 1.1
18
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Zones can be divided into two systems. Based on your requirements, the installer designates which
zones belong to Partition 1 and Partition 2, both partitions (dual area), or are not given any partition
assignment. A zone belonging to a 2 partitions is armed only when both Partition 1 and Partition 2
are armed. However, this sharing zone will be disarmed if either Partition 1 or Partition 2 is
disarmed.
The installer must program the required user code settings. These settings determine which user
codes can arm Partition 1, as well as which user codes can arm Partition 2. Codes can also be
given access to both partitions.
If your user code has access to both partitions
[*] + [USER CODE] + [#] + [1] + [2]
(Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. If the key in user code is assigned to control 2 partitions, zone indicators 1 and 2 will flash.
Enter key [1] followed by key [2].
5. The P1 and P2 indicators will illuminate and the keypad audible indicator will sound on and
off for the duration of the EXIT delay. Any bypassed zones will be shown by the flashing
zone indicators.
6. Leave the premises only via the EXIT/ENTRY zone.
7. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[1] + [1 or 2]
(Press and hold down for 2 seconds)
9. It is also possible to AWAY arm by simply enter and hold down [1] key for 2 seconds.
10. Zone indicator [1] and [2] will flash.
11. Enter key [1] followed by key [2] to both partitions.
If your user code has access to 2 partitions and you would like to arm Partition 1 only
[*] + [USER CODE] + [#] + [1] + [#]
(Leave via ENTRY/EXIT Zone)
If your user code has access to 2 partitions and you would like to arm Partition 2 only
[*] + [USER CODE] + [#] + [2] + [#]
(Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
AWAY ARMING EITHER 1 PARTITION
AWAY ARMING 2 PARTITIONS SIMULTANEOUSLY
ARMING A PARTITIONED SYSTEM